85 research outputs found

    Heart rate variability analysis in postural orthostatic tachycardia syndrome: a case report

    Get PDF
    The authors present a case of 36 year old male patient with idiopathic postural orthostatic tachycardia syndrome (POTS) diagnosed during head-up tilt testing. Power spectral analysis of heart rate variability (HRV) during the tilt test revealed that the ratio of low and high frequency powers (LF/HF) increased with the onset of orthostatic intolerance. This analysis confirmed in our patient a strong activation in sympathetic tone

    Longevity of Replaced ICD/CRT-D

    Get PDF
    Longevity of Replaced ICD/CRT-D Introduction The longevity of defibrillators (ICD) is extremely important from both a clinical and economic perspective. We studied the reasons for device replacement, the longevity of removed ICD, and the existence of possible factors associated with shorter service life. Methods and Results Consecutive patients who underwent ICD replacement from March 2013 to May 2015 in 36 Italian centers were included in this analysis. Data on replaced devices were collected. A total of 953 patients were included in this analysis. In 813 (85%) patients the reason for replacement was battery depletion, while 88 (9%) devices were removed for clinical reasons and the remaining 52 because of system failure (i.e., lead or ICD generator failure or a safety advisory indication). The median service life was 5.9 years (25th–75th percentile, 4.9–6.9) for single- and dual-chamber ICD and 4.9 years (25th–75th percentile, 4.0–5.7) for CRT-D. On multivariate analysis, the factors CRT-D device, SC/DC ICD generator from Biotronik, percentage of ventricular pacing, and the occurrence of a system failure were positively associated with a replacement procedure. By contrast, the device from Boston Scientific was an independent protective factor against replacement. Considerable differences were seen in battery duration in both ICD and CRT-D. Specifically, Biotronik devices showed the shortest longevity among ICD and Boston Scientific showed the longest longevity among CRT-D (log-rank test, P < 0.001 for pairwise comparisons). Conclusion Several factors were associated with shorter service life of ICD devices: CRT-D, occurrence of system failure and percentage of ventricular pacing. Our results confirmed significant differences among manufacturers

    Physical activity measured by implanted devices predicts atrial arrhythmias and patient outcome: Results of IMPLANTED (Italian Multicentre Observational Registry on Patients With Implantable Devices Remotely Monitored)

    Get PDF
    Background--To determine whether daily physical activity (PA), as measured by implanted devices (through accelerometer sensor), was related to the risk of developing atrial arrhythmias during long-term follow-up in a population of heart failure (HF) patients with an implantable cardioverter defibrillator (ICD). Methods and Results--The study population was divided into 2 equally sized groups (PA cutoff point: 3.5 h/d) according to their mean daily PA recorded by the device during the 30- to 60-day period post-ICD implantation. Propensity score matching was used to compare 2 equally sized cohorts with similar characteristics between lower and higher activity patients. The primary end point was time free from the first atrial high-rate episode (AHRE) of duration 656 minutes. Secondary end points were: first AHRE 656 hours, first AHRE 6548 hours, and a combined end point of death or HF hospitalization. Data from 770 patients (65\ub115 years; 66% men; left ventricular ejection fraction 35\ub112%) remotely monitored for a median of 25 months were analyzed. A PA =3.5 h/d was associated with a 38% relative reduction in the risk of AHRE 656 minutes (72-month cumulative survival: 75.0% versus 68.1%; log rank P=0.025), and with a reduction in the risk of AHRE 656 hours, AHRE 6548 hours, and the combined end point of death or HF hospitalization (all P &lt; 0.05). Conclusions--In HF patients with ICD, a low level of daily PA was associated with a higher risk of atrial arrhythmias, regardless of the patients' baseline characteristics. In addition, a lower daily PA predicted death or HF hospitalization

    Search for heavy neutral lepton production in K+ decays

    Get PDF
    A search for heavy neutral lepton production in K + decays using a data sample collected with a minimum bias trigger by the NA62 experiment at CERN in 2015 is reported. Upper limits at the 10−7 to 10−6 level are established on the elements of the extended neutrino mixing matrix |Ue4| 2 and |Uμ4| 2 for heavy neutral lepton mass in the ranges 170–448 MeV/c2 and 250–373 MeV/c2, respectively. This improves on the previous limits from HNL production searches over the whole mass range considered for |Ue4|2 and above 300 MeV/c2 for |Uμ4|2

    Measurement of the very rare K+π+ννˉK^+ \to \pi^+ \nu \bar\nu decay

    Get PDF
    The decay K+→π+νν¯ , with a very precisely predicted branching ratio of less than 10−10 , is among the best processes to reveal indirect effects of new physics. The NA62 experiment at CERN SPS is designed to study the K+→π+νν¯ decay and to measure its branching ratio using a decay-in-flight technique. NA62 took data in 2016, 2017 and 2018, reaching the sensitivity of the Standard Model for the K+→π+νν¯ decay by the analysis of the 2016 and 2017 data, and providing the most precise measurement of the branching ratio to date by the analysis of the 2018 data. This measurement is also used to set limits on BR(K+→π+X ), where X is a scalar or pseudo-scalar particle. The final result of the BR(K+→π+νν¯ ) measurement and its interpretation in terms of the K+→π+X decay from the analysis of the full 2016-2018 data set is presented, and future plans and prospects are reviewed

    Superselective cannulation of coronary sinus branch with telescopic system during left ventricular lead placement

    No full text
    We present a case of a 55-year-old man with idiopathic dilated cardiomyopathy, ejection fraction (EF) of 27%, left bundle branch block with QRS duration of 160 ms, NYHA class III, and optimal medical therapy for at least 6 months who was referred to our division for cardiac resynchronization therapy (CRT) using a biventricular pacing device. During the operation, the coronary sinus branch cannulation failed using classical angioplasty guide wire techniques. The pacing lead was successfully implanted into the posterior target vein using a telescopic dual-catheter system. www.actabiomedica.it

    Biventricular pacing and heterogeneity of ventricular repolarization in heart failure patients

    Get PDF
    The aim of our study was to evaluate the effect of cardiac resyncronization therapy (CRT) on QT dispersion (QTd), JT dispersion (JTd) and transmural dispersion of re-polarization (TDR), markers of heterogeneity of ventricular repolarization in a study population with severe heart failure

    Atrial Fibrillation in COVID-19: From epidemiological association to pharmacological implications

    No full text
    Coronavirus disease 2019 (COVID-19) outbreak is a public health emergency of international concern due to a highly pathogenic human coronavirus (HCoV), actually named severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Despite much emerging data about the epidemiological association between cardiovascular diseases and COVID-19, little is still known atrial fibrillation (AF) and its optimal management in this clinical contest. The aim of our review is to describe the pharmacological interactions between cardiovascular drugs more commonly used in AF management and experimental COVID-19 therapies, based on European (EU) and Unites States (US) summaries of product characteristics
    corecore